Jul 3 2008
Contents
 
Introduction
Overview - RECOMMENDED READING FOR NEW ICM USERS
File Menu
Graphics Move Tools
Display Tab
Light Tab
Labels Tab
PDB Search Tab
Meshes Tab
View Menu
Selections
Tables
Local DB
Sequences
Bioinfo Menu
 Content
 Secondary Structure
 Six Frame Translation
 Set Sequence Type
 Align Two Sequence
 Sequence Structure Alignment
 Align DNA vs Protein
 Multiple Sequence Alignment
 Link to Structure
 Extraxt Sub-Alignment As Is
 Cut Vertical Alignment Block
 Reorder Sequences
 Extract Unique Sequences
 Search and Align
Tools Menu - Xray
Tools Menu - 3D Predict
Tools Menu - Analysis
Tools Menu - Superimpose
Homology and Modelling
Working with Chemistry Tools
Chemsitry Menu
Docking
Ligand Editor
Animations, Slides, & Documents
ActiveICM
Movie Making
Frequently Asked Questions
Tutorial - Graphical Display
Molecular Document
Tutorial - Working with PDB Protein Structures
Tutorial - Working with Sequence Alignments
Tutorial - Ligand Binding Pocket Analysis
Tutorial - Homology and Modeling Tools
Tutorial - Crystallographic Analysis Tools
Tutorial - Working with Chemical Tables
Tutorial - Working with the Molecular Editor
Tutorial - Chemical Searching
Tutorial - Docking and Virtual Ligand Screening
 
Index
PrevICM User's Guide
15.5 Align Two Sequences
Next

To align two sequences:

  • Read into ICM two or more sequences.
  • Bioinfo/Align Two Sequences

  • Enter the name of your first sequence in the 'Sequence 1' data entry box.
  • Enter the name of your second sequence in the 'Sequence 2' data entry box.

NOTE: Any sequences already loaded into ICM can be seen by clicking on the down arrow next to the 'Sequence 1 and 2' data entry boxes. This can save typing and trying to remember what you called your sequence.

  • Enter a unique alignment name in the 'alignmentName' data entry box.
  • Select a comparison matrix from the list shown below by clicking on the arrow next to the 'comp matrix' data entry box.

  • Select the alignment algorithm you wish to use from the list shown below by clicking on the arrow next to the 'alignmentAlgorithm' data aentry box.

ZEGA - a Zero End-gap Global Alignment, that is a pairwise alignment method based on the Needleman and Wunsch algorithm modified to use zero gap end penalties. This type of alignment was first described by Michael Waterman, who called it the "fit" alignment. The paper of Abagyan and Batalov, 1997 describes the statistics of the structural significance of the alignment score and optimization of the alignment parameters for the best recognition of structurally related proteins.

H-Align - alignment method used in the Align and Score functions and find database command (as described in Batalov and Abagyan, 1999)

  • Enter the values you wish to use for Gap Open, Gap Extension and the maximum penalized gap penalty.

Gap Open The absolute gap penalty is calculated as a product of gapOpen and the average diagonal element of the residue comparison table You may vary gapOpen between 1.8 and 2.8 to analyze dependence of your alignment on this parameter. Lower pairwise similarity may require somewhat lower gapOpen parameter. A value of 2.4 (gapExtension=0.15) was shown to be optimal for structural similarity recognition with the Gonnet et. al.) matrix, while a value of 2.0 was optimal for the Blosum50) matrix ( Abagyan and Batalov, 1997).

Gap Extension The absolute gap penalty is calculated as a product of gapExtension and the average diagonal element of the residue comparison table.

maxPenalizedGap The maximum penalized gap which is used for Gap Open and Extension

  • Click OK and the alignment will be displayed in the alignment editor window at the bottom of the graphical user interface.
  • Remember to save the project or write the alignment if you wish to keep the alignment for use at another time.


Prev
Set Sequence Type
Home
Up
Next
Sequence Structure Alignment

Copyright© 1989-2004, Molsoft,LLC - All Rights Reserved.
This document contains proprietary and confidential information of Molsoft, LLC.
The content of this document may not be disclosed to third parties, copied or duplicated in any form,
in whole or in part, without the prior written permission from Molsoft, LLC.