| Mar 8 2010 |
[ ICM Convert | Optimize | Regularization | Edit Structure | MMFF | Minimize | Sample Loop | Stack | Energy Terms ]
To calculate energy, build a molecular surface and for all energy operations you need to convert a PDB file into an ICM object.
To convert a small molecule into an ICM object.
This option optimizes H, His, Asn, Gln, and Pro by maximizing hydrogen bonds and other interactions with the rest of the protein and/or with the ligand. To perform this optimization
This option is described in detail in the modeling chapter here.
Set Bond Type
Set Formal Charge
Set Chirality
Build Hydrogens
Set Tether Theory A tether is a harmonic restraint pulling an atom in the current object to a static point in space. This point is represented by an atom in another object. Typically, it is used to relate the geometry of an ICM molecular object with that of, say, an X-ray structure whose geometry is considered as a target. Tethers can be imposed between atoms of an ICM-object and atoms belonging to another object, which is static and may be a non-ICM-object. You cannot create tethers in ICM-Browser, however, if the project that you have loaded contains tethers between two objects, then they can be displayed:
Delete Tether
Set Types This option is described in detail here in the command line manual http://www.molsoft.com/man/icm-commands.html#set-type-mmff Set Charges This option is described in detail here in the command line manual http://www.molsoft.com/man/icm-commands.html#set-chargemmff Read Libraries This option is described in detail here in the command line manual http://www.molsoft.com/man/icm-commands.html#read-librarymmff
Cartesian This option is described in detail here in the command line manual http://www.molsoft.com/man/icm-commands.html#minimize-cartesian Local This option is described in detail here in the command line manual http://www.molsoft.com/man/icm-commands.html#minimize
This option is described in the Loop Modeling section.
Operations which use the ICM Biased Probability Monte Carlo method e.g. docking and loop modeling generate a stack of energy conformations. MolMechanics/Stack/View will display the conformations of a stack in a table ranked by energy. Each conformation can be viewed by double clicking on the table. A stack file will have the extension .cnf. For example, after running the sample loop algorithm a stack of different loop conformations will be generated. MolMechanics/Stack/Play This option will play the elements of the stack as a movie. You can set the number of frames for the movie and also select whether you would like ICM to interpolate between each frame. You can save this movie in avi, mpeg format using the Screen-Grabbing Movie options. MolMechanics/Stack/Add current conformation This option will add the currently displayed conformation to the stack. This is useful for experiments such as multiple receptor docking whereby you dock to a stack of conformations. MolMechanics/Stack/Store Stack in Object This option takes the current stack and stores it in a compressed form inside the specified object. The compressed stack can then be extracted with the load stack object command. Option stack of the montecarlo command stores the generated stack inside the current object automatically. MolMechanics/Stack/Delete Deletes the current stack. MolMechanics/Stack/Set conf Comparison This option compares the stack as described here: http://www.molsoft.com/man/preference.html#compareMethod and http://www.molsoft.com/man/icm-commands.html#compare MolMechanics/Stack/Recalculate Energies Recaluclates the energy of a current stack if changes have been made.
The energy function calculated for any conformation of an ICM molecular object consists of individual terms described which can be turned on and off using MolMechanics/Energy Terms. These terms are described in more detail here http://www.molsoft.com/man/terms.html
|
| Copyright© 1989-2008, Molsoft,LLC - All Rights Reserved. |
|
This document contains proprietary and confidential information of
Molsoft, LLC. The content of this document may not be disclosed to third parties, copied or duplicated in any form, in whole or in part, without the prior written permission from Molsoft, LLC. |